   power entry modules with line filter kmf www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, fuseholder 1- or 2-pole, line switch 2-pole kmf: with shield and line filter plug removal necessary for fuse replacement c14 70 c description - panel mount: snap-in version from front side - 4 functions: appliance inlet protection class i, line switch 2-pole, fuseholder for fuse-links 5 x 20 mm 1- or 2-pole, line filter in standard and medical version - quick connect terminals 4.8 x 0.8 mm approvals - vde certificate number: 126123 - ul file number: e72928 characteristics - ultra-compact design. small dimensions in front of and behind the pa - nel - all single elements are already wired - for added safety "extra-safe" fuse drawers are available fuse drawer meets requirements of medical standard iec/en 60601-1 the fuse drawer can only be opened with the aid of a tool the fuseholder is accessible from the equipment front - innovative emc-shielding with flexible steel segments for an excellent contact - qualified for use in equipment according iec/en 60950 other versions on request - fuse drawer 1-pole, plus spare fuse case - fuse drawer 2-pole, with shorting bar - other rocker marking references alternative: version without line filter k m alternative: version for screw mounting dd1 2 weblinks pd f , general product informatio n , approval s , roh s , china-roh s , mating connector s , e-stor e , schurter-stock-chec k , distributor- stock-chec k , accessorie s , wire harnes s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 4.8 x 0.8 mm panel thickness s snap-in: 1/1.5/2/2.5 mm (all steps with one variant) material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 2 w (1 pole)/ 1.4 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch rocker switch 2-pole, non-illuminated, acc. to iec 61058-1 technical detail s line filter standard and medical version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'800'000 h acc. to mil-hb-217 f
 power entry modules with line filter kmf www.schurter.com/pg0 6 emc products dimensions 42.9 mm r1.5 30.5 50 32 10.7 l 46.8 27.8 30.4 25.7 40.4 2.5 s 0.05 max. r 0.3 47.8 +0.10 -0.05 +0.10 -0.05 0 28.8 n technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1 diagrams standard version 1) line 2) load medical version 1) line 2) load derating curves 1-pole admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c 2-pole admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.4 0.6 0.4 1.0 0.8 1.2 ambient air temperature ta c
 power entry modules with line filter kmf www.schurter.com/pg0 6 emc products attenuation loss - - - - differential mode _____ common mode standard version 1 a 2 a 4 a 6 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 10 a variants fuse drawer must be ordered separately (see accessories). rated current [a] filter-type fuseholder line switch order number 1 standard version 1-pole 2-pole kmf1.1211.11 2 standard version 1-pole 2-pole kmf1.1221.11 4 standard version 1-pole 2-pole kmf1.1241.11 6 standard version 1-pole 2-pole kmf1.1261.11 10 standard version 1-pole 2-pole kmf1.1291.11 1 standard version 2-pole 2-pole kmf1.1111.11 2 standard version 2-pole 2-pole kmf1.1121.11 4 standard version 2-pole 2-pole kmf1.1141.11 6 standard version 2-pole 2-pole kmf1.1161.11 10 standard version 2-pole 2-pole kmf1.1191.11 1 medical version (m5) 1-pole 2-pole kmf1.1213.11 2 medical version (m5) 1-pole 2-pole kmf1.1223.11 4 medical version (m5) 1-pole 2-pole kmf1.1243.11 6 medical version (m5) 1-pole 2-pole kmf1.1263.11 10 medical version (m5) 1-pole 2-pole kmf1.1293.11 1 medical version (m5) 2-pole 2-pole kmf1.1113.11 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1
 power entry modules with line filter kmf www.schurter.com/pg0 6 emc products rated current [a] filter-type fuseholder line switch order number 2 medical version (m5) 2-pole 2-pole kmf1.1123.11 4 medical version (m5) 2-pole 2-pole kmf1.1143.11 6 medical version (m5) 2-pole 2-pole kmf1.1163.11 10 medical version (m5) 2-pole 2-pole kmf1.1193.11 packaging unit 20 pcs required accessor y description fusedrawer 2 fusedrawer with and without voltage selector insert fingergrip, 2-pole 4301.1401 extra-safe, 2-pole 4301.1403 fingergrip, 1-pole 4301.1405 extra-safe, 1-pole 4301.1407 ... accessorie s assorted cover s rear cover 0859.0076 wire harnes s wire harness for schurter products cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating outlets/connector s category / description appliance outletoverview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outletfurther types tokm f
 power entry modules with line filter kmf www.schurter.com/pg0 6 emc products connectoroverview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connectorfurther types tokm f ... power cordoverview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cordfurther types tokm f ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.


▲Up To Search▲   

 
Price & Availability of KMF1112311

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X